TM 55-1520-240-23-6
7-14
PREPARE FLIGHT CONTROL HYDRAULIC SYSTEM AFTER FLUSHING (RETURN
LINES)
(Continued)
7-14
LOWER CONTROLS ACTUATORS
7.
Remove bypass hose (11) and fittings (12) from
No. 2 return lines (13).
8.
Plug No. 1 return line (14) and No. 2 return line
(13).
INSPECT
NO. 1 AND NO. 2 LOWER CONTROLS MODULES
9.
Remove test hose (15) and fittings (16) from
No. 1 module return line (17) and No. 2 module
return line (18). Plug open lines.
INSPECT
7-88