TM 55-1520-240-23-6
7-283
REMOVE CARGO DOOR PRESSURE ACTUATED VALVE
(Continued)
7-283
1.
Tag and disconnect four hydraulic tubes (1) from
valve (2). Use cloths (E120) for spilled fluid. Use
gloves (E186).
2.
Remove two nuts (3), four washers (4), two
spacers (5), and two bolts (6) from valve (2).
Remove valve.
3.
Remove four nipples (7) and packings (8) from
valve (2).
FOLLOW-ON MAINTENANCE:
None
END OF TASK
7-1050