TM 55-1520-240-23-6
7-282
ADJUST CARGO DOOR SEQUENCE VALVE
(Continued)
7-282
1.
Loosen locknut (1). Turn rod end (2) clockwise
until it bottoms.
2.
Set ramp control handle (3) to UP. Raise ramp
fully up. Set ramp control handle to STOP.
3.
Turn rod end (2) until it touches cartridge (4).
4.
Set ramp control handle (3) to DN. Lower ramp
fully down. Set ramp control handle to STOP.
7-1047