TM 55-1520-240-23-5
6-191
ASSEMBLE COMBINING TRANSMISSION SUMP
(Continued)
6-191
4.
Lockwire sight gage (7) at front of sump (3) to
temperature probe (3). Lockwire two sight gages
(8) at sides of sump to drain valves (6). Use
lockwire (E231).
5.
Lockwire two temperature probes (2) at sides of
sump (3) to sump. Use lockwire (E231).
6.
Install three screens (9) and retaining rings (10).
INSPECT
ASSEMBLE SUMP COVER
Dry cleaning solvent (E162) is
flammable and toxic. It can irritate
skin and cause burns. Use only in
well-ventilated area, away from heat
and open flame. In case of contact,
immediately flush skin or eyes with
water for at least 15 minutes. Get
medical attention for eyes.
7.
Clean inside of filter housing (11) with dry
cleaning solvent (E162) and clean cloths (E120).
Check that hole (12) is free of debris. Wear
gloves (E186).
8.
Hold housing (11) so that indicating button (13)
points straight up. Push in button to lock it down.
9.
Install element (14) in housing (11).
10.
Install gasket seal (15), and housing (11) on four
studs (16). Install four washers (17) and nuts
(18). Torque nuts to 60 inch-pounds.
6-632