TM 55-1520-240-23-5
6-175
INSPECT COMBINING TRANSMISSION DEBRIS DETECTION SCREEN
6-175
INITIAL SETUP
Applicable Configurations:
All
Tools:
Goggles
Materials:
Dry Cleaning Solvent (E162)
Cloth (E120)
Brush (E86)
Gloves (E186)
Personnel Required:
Medium Helicopter Repairer
References:
Task 6-108
Equipment Condition:
Off Helicopter Task
1.
Check screen (1) for bits of metal and other
debris. Retain debris for contamination analysis
(Task 6-108).
Dry cleaning solvent (E162) is
flammable and toxic. It can irritate
skin and cause burns. Use only in
well-ventilated area, away from heat
and open flame. In case of contact,
immediately flush skin or eyes with
water for at least 15 minutes. Get
medical attention for eyes.
2.
Clean screen with solvent (E162) and brush
(E86). Wear gloves (E186) and goggles. Dry
with cloth (E120) or let air dry.
3.
Inspect screen (1) for tears. There shall be no
tears.
FOLLOW-ON MAINTENANCE:
None
END OF TASK
6-581