TM 55-1520-240-23-5
6-164
CLEAN AND INSPECT AFT ROTOR SHAFT OIL FILTER
(Continued)
6-164
1.
Remove lockwire. Remove housing (1) from plug
(2). Remove packing (3) from plug.
2.
Remove strainer element (4) from housing (1).
3.
Check strainer element (4) for metal particles.
Save particles for contamination analysis (Task
6-108).
Dry cleaning solvent (E162) is
flammable and toxic. It can irritate
skin and cause burns. Use only in
well-ventilated area, away from heat
and open flame. In case of contact,
immediately flush skin or eyes with
plenty of water for at least 15 minutes.
Get medical attention for eyes.
Do not use more than 30 psi
compressed air for cleaning purposes.
Debris propelled under pressure can
cause injury to eyes. Use source of
compressed air under 30 psi and
eye protection to prevent injury to
personnel.
4.
Clean housing (1), plug (2), and strainer element
(4). Use dry cleaning solvent (E162) and brush
(E86). Dry with low-pressure compressed air.
Wear gloves (E186).
5.
Inspect housing (1), plug (2), and strainer (4) for
damage. There shall be no damage.
6.
Install packing (3) on plug (2).
7.
Install strainer element (4) in housing (1). Install
housing on plug (2).
8.
Lockwire housing (1) to plug (2). Use lockwire
(E231).
INSPECT
FOLLOW-ON MAINTENANCE:
None
END OF TASK
6-560