TM 55-1520-240-23-5
6-160
REMOVE, INSTALL AND INSPECT AFT ROTOR SHAFT CHIP DETECTOR
PLUG
(Continued)
6-160
INSPECT PLUG
NOTE
Some metal fuzz on tip of plug is
normal.
4.
Check tip (6) of plug (3) for chips. Save chips for
contamination analysis (Task 6-108).
Dry cleaning solvent (E162) is
flammable and toxic. It can irritate
skin and cause burns. Use only in
well-ventilated area, away from heat
and open flame. In case of contact,
immediately flush skin or eyes with
plenty of water for at least 15 minutes.
Get medical attention for eyes.
5.
Clean tip (6) with dry cleaning solvent (E162) and
clean cloths (E120). Wear gloves (E186). Dry tip.
6.
Perform operational check of plug (3) (TM
55-1520-240-T).
INSTALL PLUG
7.
Install packing (5) on plug (3).
8.
Install plug (3) in chip detector body (4). Push in
and turn plug clockwise to lock it.
INSPECT
9.
Install access panel (2). Tighten four turnlock
fasteners (1).
INSPECT
FOLLOW-ON MAINTENANCE:
Close aft pylon right work platform (Task 2-2).
END OF TASK