TM 55-1520-240-23-5
6-158.3
INSTALL GENERATOR OIL OUTLET SCREENS
6-158.3
INITIAL SETUP
Applicable Configurations:
All
Tools:
Aircraft Mechanics Tool Kit, NSN 5180-00-323-4692
Torque Wrench, 30 to 150 Inch-Pounds
Materials:
Oil (E254)
Lockwire (E232)
Parts:
Packing
Personnel Required:
Medium Helicopter Repairer
Inspector
References:
TM 55-1520-240-23P
Oil (E254) is toxic. It can irritate skin
and cause burns. Avoid inhaling. Use
only with adequate ventilation. Avoid
contact with skin, eyes, or clothing.
In case of contact, immediately flush
skin or eyes for at least 15 minutes.
Get medical attention for eyes.
NOTE
Procedure is same to install No. 1 or
No. 2 generator oil outlet screen. No.
2 generator screen shown here.
1.
Coat packing (1) and thread of screen (2) with
oil (E254).
2.
Install packing (1) on screen (2). Install screen
in transmission (3). Torque screen to 80
inch-pounds.