TM 55-1520-240-23-5
6-48
PREPARE FORWARD TRANSMISSION FOR SHIPMENT OR STORAGE
6-48
INITIAL SETUP
Applicable Configurations:
All
Tools:
Aircraft Mechanics Tool Kit, NSN 5180-00-323-4692
Hoisting Eye (T32)
Work Hoist
Shipping Container (T74)
Container, 14 Quart (2)
Torque Wrench, 30 to 150 Foot-Pounds
Materials:
Fingerprint Remover (E175)
Cloths (E120)
Dry Cleaning Solvent (E162)
Gloves (E186)
Swabbing Brush (E86)
Corrosion Preventive Compound (E153 or E154)
Desiccant (E160), 16-Unit Bag (8)
Barrier Material (E81)
Tape (E388)
Personnel Required:
Medium Helicopter Repairer (2)
Inspector
References:
DA PAM 738-751
TB 55-8100-200-25
TB 750-126
Equipment Condition:
Off Helicopter Task
Forward Transmission Disassembled (Task 6-47)
General Safety Instructions:
Dry cleaning solvent (E162),
fingerprint remover (E175) and
corrosion-preventive compound (E153
or E154) are flammable and toxic.
They can irritate skin and cause
burns. Use only in well-ventilated
area, away from heat and open flame.
In case of contact, immediately flush
skin or eyes with water for at least
15 minutes. Get medical attention
for eyes.
6-174