REPLACE NICKEL EROSION CAP (AVIM)
(Continued)
5-66
NOTE
Working life of adhesive (E41 or E43)
is about 30 minutes.
18.
Apply adhesive (E43) as follows:
a.
Coat bonding surface (7) with adhesive, using
stiff-bristle brush. Wear gloves (E184.1).
b.
Position scrim cloth (E325) (10) on bonding
surface. (7). Work scrim cloth into adhesive
(E43) until completely coated.
c.
Apply heavy coat of adhesive (E43) to inside
of erosion cap (3). Be sure inside leading
edge is well covered.
19.
Position erosion cap (3) on bonding surface (7).
Seat cap firmly. Apply tape (E387) 2 inches wide
across cap to hold cap on blade. Start at tip end.
Position tape strips about 6 inches apart.
NOTE
Place tape so that some strips fall
about halfway between damps when
fixture (T69) is installed.