TM 55-1520-240-23-4
5-60
REMOVE CENTRIFUGAL DROOP STOP SUPPORT AND BLOCKS
(Continued)
5-60
2.
Have helpers lift blade (1) until fixed droop stop
(4) on shaft (5) is clear of interposer block (6).
Support blade.
3.
Pull balancing arm (7) out to clear interposer
block (6). Have helpers lower blade (1) until fixed
droop stop (4) rests against flight stop (8).
5-258