TM 55-1520-240-23-4
5-61
INSTALL CENTRIFUGAL DROOP STOP SUPPORT AND BLOCKS
5-61
INITIAL SETUP
Applicable Configurations:
All
Tools:
Aircraft Mechanics Tool Kit, NSN 5180-00-323-4692
Torque Wrench, 30 to 150 Inch-Pounds
Materials:
Cloth (E120)
Lockwire (E229)
Epoxy Primer (E292 and E292.1)
Gloves (E184.1)
Personnel Required:
Medium Helicopter Repairer (5)
Inspector
References:
TM 55-1520-240-23P
Task 5-49
General Safety Instructions:
Do not lower blade suddenly.
Personnel can be injured if blade is
lowered suddenly while droop stop
work is in progress.
Epoxy primers (E292 and E292.1) are
flammable and toxic. They can irritate
skin and cause burns. Use only with
adequate ventilation, away from heat
and open flame. In case of contact,
immediately flush skin or eyes with
water for at least 15 minutes. Get
medical attention for eyes.
5-260