TM 55-1520-240-23-10
12-14
REPLACE FIRE PULL HANDLE LAMP
(Continued)
12-14
REMOVE LAMP
3.
Remove holder lens (8) and seal or packing (9)
from handle (7).
4.
Separate lamp (10) from holder (8).
INSTALL LAMP
5.
Install lamp (10) in holder (8).
6.
Install holder (8) and packing (9) in handle (7).
INSTALL COVER ASSEMBLY WITH 17
7.
Position bottom cover (5) under fire handle (7).
8.
Position lid (4) on top of fire handle (7).
Do not tighten self-locking nut when
installing filter holder. Accidental
actuation of fire extinguisher may
result.
NOTE
Tab of filter holder on left fire handle is
on right edge. Tab of filter holder on
right fire handle is on left edge.
9.
Position filter holder (5) on fire handle (7).
10.
Install two screws (1), washers (2), and
self-locking nuts (3) in fire handle (7).
INSPECT
FOLLOW-ON MAINTENANCE:
Perform operational check of fire extinguisher system
(TM 55-1520-240-T).
END OF TASK
12-44