TM 55-1520-240-23-10
16-35
INSTALL FORWARD OR AFT CARGO HOOK INTERNAL MANUAL RELEASE
CABLE
(Continued)
16-35
18.
Tighten locknut (14) against clevis (15). Lockwire
locknut and clevis together. Use lockwire (E231).
19.
Position window (22) on retaining bolt (20).
20.
Torque bolts (20 and 21) to 40 inch-pounds.
Lockwire bolts, cable adapter (25) and nut (26)
together. Use lockwire (E231).
FOLLOW-ON MAINTENANCE:
Perform operational check (TM 55-1520-240-T).
Close center hook access door (Task 2-2).
Close right center cabin floor panel (Sta 240 to 320)
or right center cabin floor panel (Sta 360 to Sta
486) (Task 2-207).
END OF TASK
16-190