TM 55-1520-240-23-10
16-3.4
INSTALL CENTER HOOK MANUAL RELEASE CABLE
(Continued)
16-3.4
6.
Check that cable (1) protrudes past bracket
(10) 0.70 to 0.75 inch. This dimension is for
initial installation and may change during final
adjustment.
7.
Hold jam nut (12). Tighten jam nut (13). Lockwire
nuts together. Use lockwire (E231).
8.
Install bolt (14) and washer (15) securing cable
(1) to bellcrank (11). Torque bolt 20 to 35
inch-pounds.
9.
Lockwire bolt (14). Use lockwire (E231).
INSPECT
FOLLOW-ON MAINTENANCE:
Adjust cable (Task 16-3.5).
END OF TASK