TM 55-1520-240-23-1014-3.1REPLACE WINCH LIMIT SWITCHES(Continued)14-3.1INSTALL WINCH HOUSING COVER19.Connect lower end of spring (4) to wire bundle(6). Use tie wrap (E374).20.Position cover (3). Lift cover enough to attachspring (4) to underside of cover at bracket (5).Lower cover.21.Secure cover (3) to housing with six screws (1)and washers (2).22.Lockwire screws (1) together in pairs. Uselockwire (E231).INSPECTFOLLOW-ON MAINTENANCE:Perform operational check (TM 55-1520-240-T).Install stowage container (Task 14-20).Install heater compartment acoustic blanket (Task2-210).END OF TASK14-21