19.
Connect lower end of spring (4) to wire bundle
(6). Use tie wrap (E374).
20.
Position cover (3). Lift cover enough to attach
spring (4) to underside of cover at bracket (5).
Lower cover.
21.
Secure cover (3) to housing with six screws (1)
and washers (2).
22.
Lockwire screws (1) together in pairs. Use
lockwire (E231).
INSPECT
FOLLOW-ON MAINTENANCE:
Perform operational check (TM 55-1520-240-T).
Install stowage container (Task 14-20).
Install heater compartment acoustic blanket (Task
2-210).
END OF TASK
14-21