TM 55-1520-240-23-10
13-49
INSTALL HEATER FUEL SOLENOID VALVE
13-49
INITIAL SETUP
Applicable Configurations:
All
Tools:
Aircraft Mechanics Tool Kit, NSN 5180-00-323-4692
Materials:
Lockwire (E231)
Parts:
Packing
Personnel Required:
Medium Helicopter Repairer
Inspector
References:
TM 55-1520-240-23P
General Safety Instructions:
All regulations and instructions
for handling fuels shall be strictly
observed.
1.
Install strainer (1) in end of valve (2) opposite
arrow (3).
2.
Install two reducers (4) and packings (5).