TM 55-1520-240-23-10
13-48
REMOVE HEATER FUEL SOLENOID VALVE
13-48
INITIAL SETUP
Applicable Configurations:
All
Tools:
Aircraft Mechanics Tool Kit, NSN 5180-00-323-4692
Grounded Container, Two Quart
Materials:
Cloths (E135)
As Required
Personnel Required:
Medium Helicopter Repairer
Equipment Conditions:
Battery Disconnected (Task 1-39)
Electrical Power Off
Helicopter Grounded (Task 1-29)
Right Aft Intertank Access Door Opened (Task 2-2)
General Safety Instructions:
All regulations and instructions
for handling fuels shall be strictly
observed.
1.
Remove lockwire and disconnect electrical
connector (1).
2.
Disconnect two fuel hoses (2). Use container
and cloths (E135) for spilled fuel. Plug hoses.
3.
Remove two bolts (3) and washers (4). Remove
valve (5).
13-150