  882    883    884    885    886  887  888    889    890    891    892  
TM  55-1520-240-23-9 11-231 REMOVE  AFT LCT YOKE BUSHINGS  (AVIM) (Continued) 11-231 7. Remove  slip  fit bushing  (9) from  bushing  (10). Do  not heat  yoke  over 230ºF (110ºC). Damage  to  shotpeened  surface  will result. 8. Heat yoke  lug  (12) with  heat  gun.  Do  not exceed 230ºF (110ºC).  Use  pyrometer  to  measure temperature.  Wear Kevlar gloves  (E187). 9. Position  large  bushing  (2) against  outer surface of lug  (12).  Wear Kevlar gloves  (E187). 10. Install  bolt (3)  through  plate  (4), bushing  (2), lug (12),  and  bushing  (5).   Install  washer  (6)  and nut  (7). 11. Tighten  nut  (7)  to  push  bushings (13,  14, and 15)  from  lug  (12). 12. Remove  nut  (7),  washer (6),  bushing  (5),  bolt (3), plate  (4),  and  bushing  (2).  Remove  bushings (13, 14,  and  15) from  bushing  (2). 13. Remove  large  washer (16) from  lug  (12). 11-897