  884    885    886    887    888  889  890    891    892    893    894  
TM  55-1520-240-23-9 11-232 INSTALL AFT LCT YOKE  BUSHINGS  (AVIM) 11-232 INITIAL  SETUP Applicable Configurations: All Tools: Aircraft  Mechanic’s Tool  Kit, NSN 5180-00-323-4692 Electric Gun  Heater, NSN 4940-00-785-1162 Pyrometer Arbor  Press Adapters Container,  2  Quart Materials: Carbon  Dioxide  (Dry Ice)  (E92) Methanol  (E243) Cloth  (E120) Epoxy Primer  (E292/E292.1) Gloves  (E184.1) Kevlar  Gloves  (E187) Personnel  Required: Medium  Helicopter Repairer Inspector References: TM  1-1520-253-23 TM  55-1520-240-23P General Safety Instructions: Epoxy  primer  (E292/E292.1)  is flammable  and  toxic.   It  can  irritate skin  and  cause  burns.  Use  only  with adequate  ventilation,  away  from heat and  open  flame.   Avoid  contact  with skin,  eyes,  or  clothing.   In  case  of contact, immediately flush skin  or eyes with  water for  at  least  15 minutes. Get medical  attention  for eyes. 11-899