TM  55-1520-240-23-9 11-137 ADJUST PITCH OR ROLL BALANCE  SPRINGS 11-137 INITIAL  SETUP Applicable Configurations: All Tools: Aircraft  Mechanic’s  Tool  Kit,  NSN  5180-00-323-4692 Plumb  Bob Materials: Masking  Tape  (E388) Personnel  Required: Medium  Helicopter  Repairer Inspector Equipment  Condition: Battery  Connected  (Task  1-39) Electrical  Power  On Hydraulic  Power  On Closet  Acoustic  Blanket  Removed  (Task  2-107) Closet  Backup  Panel  Removed  (Task  2-2) 1. Press  CENTERING  DEVICE  RELEASE  button (1)  on  grip  (2)  of  copilot’s  control  stick  (3).  Center control  stick.  Release  button. 2. Position  plumb  bob  (4)  above  and  near  grip  (2). Hold  plumb  bob  in  place  by  taping  cord  (5)  to cockpit  ceiling  (6).  Use  tape  (E388). 3. Repeat  step  1. 4. Check  control  stick  (3).  Stick  must  remain  within 1  inch of  forward  or  aft,  and  right  or  left  of  center position.  If  stick  does  not  move,  go  to  step  12.  If stick  moves  forward  or  aft  perform  steps  5  thru 8.   If  stick  moves  right  or  left,  perform  steps  9 thru  12. INSPECT 11-599