• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
AFCS INTERFACE TEST (Continued) TEST 22 CYCLIC MAGNETIC  BRAKE  TEST (BOTH)
AFCS  INTERFACE  TEST (Continued) TEST 24 HYDRAULIC PRESSURE SWITCH  TEST (BOTH)

TM-55-1520-240-23-9 CH-47D Heilcopter Manual
Page Navigation
  1177    1178    1179    1180    1181  1182  1183    1184    1185    1186    1187  
TM  55-1520-240-23-9 11-280 AFCS  INTERFACE  TEST (Continued) 11-280 TEST  23 COLLECTIVE  MAGNETIC BRAKE TEST (NO.  1) 149. Set AFCS SYSTEM  SEL  switch  (1) to  1. 150. Set METER  SOURCE  switch  (3) to  DISCRETE MON. 151. Set DISCRETE SIGNAL  MONITOR  switch  (34) to  SEL  1. 152. Set SIGNAL  SEL  1  switch  (54)  to  CLTV  MAG BRK ON.  STATUS  B  light (39) shall  come  on. 153. Press THRUST CONT  BRAKE  TRIGGER switch (26).  STATUS  A light  (37) shall  come  on.  Read digital  display  (6).   Reading  shall  be  +26 to +30 VDC.  Stick  (27)  shall  move  freely.   Release THRUST  CONT  BRAKE TRIGGER  switch. END  COLLECTIVE  MAGNETIC BRAKE TEST (NO. 1) 11-1196