• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
AFCS INTERFACE TEST (Continued) TEST  21 ROLL  BEEP  TRIM  TEST  (BOTH)
AFCS INTERFACE TEST (Continued) TEST  23 COLLECTIVE  MAGNETIC BRAKE TEST (NO.  1)

TM-55-1520-240-23-9 CH-47D Heilcopter Manual
Page Navigation
  1176    1177    1178    1179    1180  1181  1182    1183    1184    1185    1186  
TM  55-1520-240-23-9 11-280 AFCS  INTERFACE  TEST (Continued) 11-280 TEST 22 CYCLIC MAGNETIC  BRAKE  TEST (BOTH) 144. Set  AFCS  SYSTEM  SEL  switch  (1)  to  1  or  2. (System  under  test.) 145. Set METER  SOURCE  switch  (3)  to  DISCRETE MON. 146. Set DISCRETE  SIGNAL  MONITOR  switch  (34) to  SEL  1. 147. Set SIGNAL  SEL  1  switch  (54) to  CYCLIC MAG BRAKE ON.  STATUS  B  light  (39) shall come  on. 148. Press  CENTERING  DEVICE  RELEASE  switch (55).  STATUS  A  light  (37)  shall  come  on.   Read digital  display  (6).   Reading  shall  be  +26.0  to +30.0 VDC.  Check  stick (32) and  pedals  (56). They  shall  move  freely in  all  directions.  Release switch. END  CYCLIC MAGNETIC  BRAKE  TEST (BOTH) 11-1195