AFCS INTERFACE TEST (Continued) TEST  15 VERTICAL GYRO PITCH ATTITUDE  TEST (BOTH)

TM-55-1520-240-23-9 CH-47D Heilcopter Manual
Page Navigation
  1168    1169    1170    1171    1172  1173  1174    1175    1176    1177    1178  
TM  55-1520-240-23-9 11-280 AFCS  INTERFACE  TEST (Continued) 11-280 TEST 14 VERTICAL GYRO VALIDITY TEST (BOTH) 84. Set  AFCS  SYSTEM  SEL  switch  (1)  to  1  or  2. (System  under  test.) 85. Set METER  SOURCE  switch  (3)  to  DISCRETE MONITOR. 86. Set DISCRETE  SIGNAL  MONITOR  switch  (34) to  SEL  2 and  SIGNAL SEL  2  switch  (35) to  VERT GYRO  VALID.  Check  gyro  indicator OFF  flag (36).  Flag  shall  disappear.  Read  digital  display (6).  Reading  shall  be  -0.5 to +0.5 VDC. STATUS A  light  (37)  shall  come  on. 87. Open  VGI  circuit  breaker  (38)  (if  system  #2  is under  test,  pilot side  or copilot  side  for #1  sys). Read  digital display (6).  Reading  shall  be  +4.0 to +6.0  VDC. STATUS  A light  (37) shall go  out and STATUS  B  light  (39)  shall  come  on. 88. Close  VGI  circuit  breaker  (38).  (System  under test.)   STATUS  B  light  (39)  shall  go  out  and STATUS  A  light  (37)  shall  come  on. END VERTICAL GYRO VALIDITY  TEST (BOTH) 11-1187