TM-55-1520-240-23-9 CH-47D Heilcopter Manual
Page Navigation
  1081    1082    1083    1084    1085  1086  1087    1088    1089    1090    1091  
TM 55-1520-240-23-9 11-277 BENCH TEST AFCS COMPUTER (AVIM)     (Continued) 11-277 TEST 6 YAW AXIS TEST NOTE Perform preliminary procedure before test. (Refer to TM 55-4920-430-13.) 348. Set METER switch (6) to DC. 349. Set METER RANGE switch (7) to 2V. 350. Set CIRCUIT SELECT TENS switch (8) to 30. 351. Set CIRCUIT SELECT A UNITS switch (18) to 0. 352. Set CIRCUIT SELECT A/B SELECT switch (9) to A. Measure and record V1 AC/DC VOLTMETER (10) reading. Reading shall be  -1.31 to +1.31. 353. Set RESPONSE TEST MODE switch (43) to ON. 354. Set ANALOG SIGNALS ALL SELECT switch (37) to HDG. 355. Set DISCRETE SIGNALS CYCLIC BRAKE switch (27) to 1. 356. Set RESPONSE TEST TIME DELAY-SEC switches (40) to 0.2. 357. Set ANALOG SIGNALS DIR CPT switch (33) to 2. 358. Set METER RANGE switch (7) to 20V. Read and record V2 AC/DC VOLTMETER (10) reading. 359. Set RESPONSE TEST STIM switch (44) to APPLY. When HOLD lamp (45) comes on, read and record V3 AC/DC VOLTMETER (10) reading. 11-1102