TM  55-1520-240-23-9 11-270 DISASSEMBLE  AFCS  CONTROL PANEL (AVIM) (Continued) 11-270 15. Remove  nut  (21)  and  washer (22)  from  rotary switch  (23). 16. Remove  switch  (23) from  mounting  plate  (19). 17. Remove  locking  ring  (24) from  switch  (23). 18. Tag  and  disconnect  five  terminal  lugs (25) by removing  five  screws (26) and  washers  (27). NOTE Removal  of three  pushbutton  switches is  the  same.   RAD  ALT  ENGAGE switch  is shown  here. 19. Tag  and  disconnect  11  wires  (28).   Use insertion/extraction  tool.  Remove  wire  ties  (29). Be  careful  when  removing  lamp carrier.   Lamp  carrier  is  attached to  pushbutton  switch  by  a  sliding retainer.  Pull  lamp  carrier out carefully and  only enough  to  rotate  down. 20. Pull lamp  earner (30) out  and  turn  down. 21. Loosen  two  screws  (31)  to  allow tabs  (32)  to rotate  in  toward  switch  (33)  freeing  retainer sleeve  (34)  and  adapter sleeve  (35). 22. Slide  pushbutton  switch  (33)  out  of  mounting plate  (19).   Tag  switch. 11-1023