TM  55-1520-240-23-7 8-22.1 REMOVE  NO.  1 OR  NO.  2 TORQUE SIGNAL PROCESSOR/POWER  SUPPLY 8-22.1 INITIAL  SETUP Applicable Configurations: With    74 Tools: Electrical  Repairer’s Tool Kit, NSN 5180-00-323-4915 Materials: Paper  Tags  (E264) Personnel  Required: Aircraft  Electrician Equipment  Conditions: Battery Disconnected  (Task  1-39) Electrical  Power Off Hydraulic  Power Off NOTE The  procedure  is the  same  to  remove the  No.   1  or  No.   2  torque  signal processor/power supply.  The  No.  2 torque  signal processor/power supply is  shown  here. 1. Tag  and  disconnect  two  connectors  (1)  from torque  signal  processor/power supply  (2).   Use paper  tags  (E264). 2. Remove  four  screws  (3) and  washers (4). 3. Remove  torque  signal  processor/power supply (2). FOLLOW-ON MAINTENANCE: None END  OF  TASK 8-69