TM 55-1520-240-23-7
9-100
INSTALL OVERHEAD PANEL PANELS
(Continued)
9-100
TROOP WARN/HEATING PANEL
5.
Install TROOP WARN/HEATING panel (36) as
follows:
a.
Position panel (36) on panel (2). Tighten four
screws (37).
b.
Remove tape. Connect and solder six wires
(38) to five lamps (39). Remove tags.
c.
Remove tape. Connect and solder eight wires
(40) to three switches (41). Remove tags.
d.
Remove tape. Connect 12 wires (42) to four
switches (43) by installing washers (44) and
screws (45). Remove tags.
INSPECT
NOTE
If no other panels are to be installed,
go to step 13.
9-393