TM 55-1520-240-23-7
9-51
REMOVE APU GENERATOR CONTACTOR
(Continued)
9-51
NOTE
Procedure is same for removal of
APU Generator Contactor from No.
1 or No. 2 power distribution panel.
Removal of APU Generator Contactor
from No. 2 power distribution panel is
shown here.
1.
Loosen six fasteners (1) and open power
distribution panel door (2).
2.
Remove two screws (3) and washers (4).
Remove contactor cover (5).
3.
Tag and disconnect 12 wires (6) from contactor
(7) by removing 9 nuts (8) and washers (9). Tape
ends. Use tape (E385).
4.
Disconnect electrical connector (10).
5.
Remove four bolts (11) and washers (12).
Remove contactor (7).
FOLLOW-ON MAINTENANCE:
None
END OF TASK
9-151