INSTALL NO.  2 GENERATOR  CONTACTOR (Continued)
REMOVE  APU  GENERATOR CONTACTOR (Continued)

TM-55-1520-240-23-7 CH-47D Heilcopter Manual
Page Navigation
  500    501    502    503    504  505  506    507    508    509    510  
TM  55-1520-240-23-7 9-51 REMOVE  APU  GENERATOR  CONTACTOR 9-51 INITIAL  SETUP Applicable  Configurations: All Tools: Electrical  Repairer’s Tool  Kit, NSN  5180-00-323-4915 Materials: Paper  Tags  (E264) Tape  (E385) Personnel  Required: Aircraft  Electrician Equipment  Condition: Battery Disconnected  (Task  1-39) Electrical  Power  Off Hydraulic  Power  Off 9-150