TM 55-1520-240-23-7
8-100
REMOVE HYDRAULIC MAINTENANCE PANEL COMPONENTS
(Continued)
8-100
NOTE
Procedure is the same to remove
eight indicator mount clamps.
Removal of No. 1 FLIGHT
CONTROL HYDRAULIC PRESSURE
INDICATOR MOUNT CLAMP is
shown here.
12.
Remove indicator mount clamp as follows:
a.
Remove round head clamp screw (55) from
clamp (56).
b.
Remove flat head retainer screw (57) from
clamp (56).
c.
Tag and remove clamp mount (56) from panel
(9).
FOLLOW-ON MAINTENANCE:
None
END OF TASK
8-318