TM  55-1520-240-23-7
8-100
REMOVE HYDRAULIC MAINTENANCE PANEL COMPONENTS
(Continued)
8-100
8.
Remove  UTILITY  HYDRAULIC  RESERVOIR
LEVEL  check switch  as  follows:
a.
Tag  and  unsolder two  wires (40) from  switch
(41).   Remove  lacing  tape  and  shrink tubing
as  necessary.
b.
Remove  nut  (42)  and  lockwasher (43)  from
switch  (41).
c.
Tag  and  remove  switch  (41) from  panel  (9).
NOTE
Procedure  is  the  same  to  remove  30
terminal modules  using  the  CTJ-R06
module  extraction  tool.  Removal  of
10  diode  modules requires using  the
CTJ-R  12  module  extraction  tools.
Removal  of  TB2-1  is shown  here.
9.
Remove  TB2-1  terminal  module  as follows:
a.
Tag  and  disconnect  twelve  wires  (44)  from
module  (45).  Use  insertion/removal  tool.
b.
Tag  and  remove  module  (45) from  module
mounting  track  (46).  Use  module  extraction
tool.
8-316