TM  55-1520-240-23-7 8-80.5.1 TEST AND ADJUST FUEL QUANTITY INDICATOR  USING  PSD  60-1AF FUEL QUANTITY TEST SET (Continued) 8-80.5.1 23. Adjust  COMP  vernier  (V-1)  until  LCD  display reads  486.4 pf  (Figure  15). 24. Rotate  tester  FUNCT  switch  (S-2)  to  SIM  TU  & COMP. 25. Disconnect cable  300W7  from  right  MAIN  tank connector  057W2  at  access  panel  114PS518. 26. Connect  PSDAF-106  "T"  cable  (Figure  10)  (J-2) to  300W7  plug  disconnected  above.  DO  NOT connect  (P-2)  to  tank  connector. 27. Disconnect 300W4  from  RIGHT  FWD  AUX  tank connector  057W1  at  access  panel  114PS518. 28. Connect  PSDAF-106  "T"  cable  (Figure  10)  (J-1) to  300W4  plug  disconnected  above.  DO  NOT connect  (P-1)  to  tank  connector. 29. Rotate  Fuel Quantity  Select  switch  in  cockpit  to TOTAL  (Figure  16). 30. Slide  Fuel  Quantity  Indicator  out  of  instrument panel  in  cockpit  (Task  8-97). 31. To  identify trimmer  adjustments (Figure  17). 32. Connect and  power  AGPU  (TM  55-1730-229-12), or  turn  ON  aircraft  APU  (Task  15-1.5). 33. Adjust "E" trimmer  marked  "T"  for  Total  Fuel until digital  total  fuel indication  reads  "0000". 34. Verify that dial  indication  (pointer)  is  out  of  sight. 8-241







Western Governors University

Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved. Design by Strategico.