TEST AND ADJUST FUEL QUANTITY INDICATOR USING PSD 60-1AF FUEL QUANTITY TEST SET (Continued) PART III. TESTING AND TROUBLESHOOTING FUEL QUANTITY SYSTEM

TM-55-1520-240-23-7 CH-47D Heilcopter Manual
Page Navigation
  230    231    232    233    234  235  236    237    238    239    240  
TM 55-1520-240-23-7 8-80.5.1 TEST AND ADJUST FUEL QUANTITY INDICATOR USING PSD 60-1AF FUEL QUANTITY TEST SET     (Continued) 8-80.5.1 58. Disconnect PSDAF-106 "T" cable from 300W7 and 300W4 (Figure 10). 59. Reconnect harnesses 300W2 thru 300W7 as follows: TANK HARNESS# TANK CONN# RIGHT MAIN 300W7 057W2 LEFT MAIN 300W6 057W9 FWD RT AUX 300W4 057W1 FWD LT AUX 300W2 057W10 AFT RT AUX 300W5 057W5 AFT LT AUX 300W3 057W6 60. Turn tester OFF and store grounding cable harness in lid. 361.7  pf 1 Read and record cable LOZ-HIZ capacitance ____pf 2 Subtract line 1 from 361.7pf.  Result is ____pf 3 Select SIM TU ONLY. Adjust "E" trimmer marked "D" for  0 lb ____lb 4  Select SIM TU & COMP. Adjust "F" trimmer marked "D" for  2200 lb ____lb 5 Select SIM TU ONLY. Readjust "E" trimmer as necessary for  0 lb ____lb FIGURE 23.1.  DIAL CALIBRATION — WORKSHEET 8-245