TM 55-1520-240-23-7
8-80.5.1
TEST AND ADJUST FUEL QUANTITY INDICATOR USING PSD 60-1AF FUEL QUANTITY
TEST SET
(Continued)
8-80.5.1
17.
Connect AUX CP lead to INDICATOR COMP
terminal (J-3) on tester (Figure 1).
18.
Rotate tester FUNCT switch (S-2) to MEASURE
INT.
19.
Select "070" on TU decade (D-1) (Figure 12).
20.
Adjust TU vernier (V-1) to read 723.4 pf on tester
LCD (Figure 13).
21.
Rotate SELECT switch (S-3) on tester to COMP.
22.
Select "46" on COMP decade (D-2) (Figure 14).
8-240