  154    155    156    157    158  159  160    161    162    163    164  
TM  55-1520-240-23-7 8-58 TEST TRANSMISSION  OIL  PRESSURE  SELECTOR  SWITCH  OR  INDICATOR (AVIM) (Continued) 8-58 TRANSDUCER  CIRCUIT TEST 16. Set selector  switch  knob  (3)  to  SCAN. NOTE Without   17  , SCAN  dial lamp  remains on  when  selector  switch  is at SCAN. 17. Adjust FWD  resistor  (11)  three turns  clockwise. 18. Check selector  switch  (2).  Without   17  , FWD  dial lamp  shall  come  on  as  resistor  (11)  is adjusted. 19. Check  indicator  (5).   Indicator  shall  read  70 psi. Adjust  FWD  resistor  (11)  to  100  percent  (full counterclockwise). 20. Repeat steps 17, 18,  and  19  at AFT  resistor  (12), MIX  resistor  (13), LEFT  resistor  (14), and  RIGHT resistor  (15). SENSITIVITY  TEST 21. Adjust FWD  resistor  (11)  clockwise  until indicator (5)  reads  20 psi.  Record  FWD  resistor  setting. 22. Adjust FWD  resistor  (11)  counterclockwise  until pointer  of  indicator  (5)  just  begins  to  move. Record  FWD  resistor  setting. 23. Compare  settings  for  FWD  resistor  (11)  in  steps 21  and  22.   Difference  shall  be  less  than  1 percent. 24. Repeat steps  21, 22,  and  23  four  times.  Use  40, 50,  70,  and 90 psi as starting  points.   Then  go to  step  25. 25. Repeat steps  21, 22,  and  23  five  times.  Use  90, 70,  50,  40,  and  20  psi  as starting  points  and adjust  FWD  resistor  (11)  clockwise.  Then  go  to step  26. 8-169







Western Governors University

Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved. Design by Strategico.