TM  55-1520-240-23-7 8-57 MISCELLANEOUS  INSTRUMENTS (Continued) 8-57 HYDRAULIC LOW PRESSURE WARNING  SYSTEM Description Each  of the  three  hydraulic systems contains a  pressure switch  that  causes a  caution  light on  the  master  caution panel  to  come  on  with  decreasing  system  pressure.  Two of the  switches have  additional  functions.  The  No.  1  and No.   2  boost  pressure  switches  signal  their  respective AFCS  computers  when  the  hydraulic  systems  are pressurized.  The  switches are  also  used  as an  interlock to  prevent turning  off  a  good  system  when  one  system has  malfunctioned. NO  BREAK  -  WORK  HARDER The  hydraulic low  pressure  switch  opens  at  increasing pressure  below  1,400 psi.  This turns the  caution  light off.   It  closes  at  a  decreasing  pressure  between  2,050 and 1,950 psi.  This turns the  caution  light on.  The  utility system  pressure  switch  is on  the  utility system  pressure control  module.  The  No.  1  and  No.  2  hydraulic  system low  pressure  switches are  on  the  No.  1  and  No.  2  power control  modules  respectively. END  OF  TASK 8-164