TM  55-1520-240-23-5 6-67 INSTALL COMBINING TRANSMISSION FORWARD OUTPUT SHAFT OIL SEAL 6-67 INITIAL  SETUP Applicable Configurations: All Tools: Powertrain   Repairer’s  Tool  Kit,   NSN 5180-00-003-5267 Gun  Heater Pyrometer Aluminum Tube, 3-1/2  Inch  OD,  1/8  Inch-Thick  Wall, 1 to  6  Inches  Long Torque  Wrench,  30  to  150  Inch-Pounds Materials: Gloves  (E186) Dry  Cleaning  Solvent  (E162) Cloths  (E120) Oil  (E254) Kevlar  Gloves  (E187) Parts: Packings Personnel  Required: Aircraft  Powertrain  Repairer Inspector References: TM  55-1520-240-23P Dry  cleaning  solvent  (E162)  is flammable  and  toxic.   It  can  irritate skin  and  cause  burns.   Use  only  in well-ventilated  area, away  from  heat and  open  flame.   In  case  of contact, immediately flush  skin  or eyes  with water  for  at  least 15 minutes.   Get medical  attention  for eyes. 1. Clean  seal  retainer (1).  Use  dry cleaning  solvent (E162) and  cloths  (E120).  Wear  gloves (E186). 6-255