REPAIR  FORWARD  SWASHPLATE  STATIONARY RING (AVIM) (Continued)
REPAIR  AFT SWASHPLATE  STATIONARY  RING (AVIM)

TM-55-1520-240-23-4 CH-47D Heilcopter Manual
Page Navigation
  707    708    709    710    711  712  713    714    715    716    717  
TM  55-1520-240-23-4 5-128 INSPECT AFT SWASHPLATE  STATIONARY  RING 5-128 INITIAL  SETUP Applicable  Configurations: All Tools: Technical Inspection  Tool Kit, NSN  5180-00-323-5114 Materials: None Personnel  Required: Inspector Equipment  Condition: Off  Helicopter  Task 1. Check  for  nicks  or  scratches in  critical  areas (1) of stationary  ring  (2).   Damage  less  than  0.005 inch in  depth  shall  be  accepted  without  rework. Blend  repair  damage  0.005 inch to 0.040 inch in depth  without  exceeding  10  percent  of material thickness  (Task 5-129). 2. Check for  nicks or  scratches  in  all  other  surfaces of stationary  ring  (2).   Damage  less  than  0.015 inch in  depth  shall  be  accepted  without  rework. Blend  repair  damage,  0.015  inch to 0.040 inch in  depth  without exceeding  10  percent  of material  thickness  (Task  5-129). FOLLOW-ON  MAINTENANCE: None END  OF  TASK 5-712