TM 55-1520-240-23-1 1-59.1 POWER DRAIN UTILITY HYDRAULIC SYSTEM RESERVOIR 1-59.1 INITIAL SETUP Applicable Configurations: All Tools: Hydraulic Test Stand Aircraft Mechanic’s Tool Kit, NSN 5180-00-323-4692 Materials: Goggles (E473) Personnel Required: CH-47 Helicopter Repairer Aircraft Pneudraulics Repairer References: TM 1-1520-240-10 TM 55-4920-335-14 TM 55-4920-373-14&P Equipment Condition: Battery Connected (Task 1-39) Electrical Power Off Hydraulic Power Off Hydraulic Connection Access Panel Open (Task 2-2) Cargo Ramp  Fully  Up or  Fully  Down  (TM 55-1520-240-T) General Safety Instructions: WARNING Make sure all connections are tight before operating hydraulic test stand. High-pressure fluid from test stand can injure personnel. WARNING Hydraulic fluid (E199) is toxic.  It can irritate skin and cause burns.  Avoid inhaling.  Use only with adequate ventilation.  Avoid contact with skin, eyes, or clothing.  In case of contact, immediately flush skin or eyes for at least  15 minutes.  Get medical attention for eyes. 1. Remove dust cover (1) from utility system RETURN connection (2). 2. Connect test stand return line (3) to utility RETURN connection (2). 1-230 Change 3