TM 55-1520-240-23-9
11-251.2
INSTALL BELLCRANK SUPPORT FITTINGS STA 482
11-251.2
INITIAL SETUP
Applicable Configurations:
All
Tools:
Aircraft Mechanics Tool Kit, NSN 5180-00-323-4692
Torque Wrench, 30 to 150 Inch-Pounds
Torque Wrench, 100 to 750 Inch-Pounds
Workstand
Materials:
Epoxy Primer (E292)
Gloves (E184.1)
Cloths (E120)
Dry Cleaning Solvent (E162)
Personnel Required:
Medium Helicopter Repairer (2)
Inspector
Equipment Condition:
Battery Disconnected (Task 1-39)
Electric Power Off
Hydraulic Power Off
Pylon Doors Open (Task 2-2)
Cargo Ramp Open and Level (TM 55-1520-240-T)
General Safety Instructions:
Dry cleaning solvent (E162) is
combustible and toxic. Avoid contact
with skin, eyes, or clothing. Avoid
inhaling. Use only with adequate
ventilation, away from open flame. In
case of contact, immediately flush
skin or eyes with water for at least
15 minutes. Get medical attention
for eyes.
Epoxy primer (E292) is flammable
and toxic. It can irritate skin and
cause burns. Use only with adequate
ventilation, away from heat and
open flame. Avoid contact with skin,
eyes, or clothing. In case of contact,
immediately flush skin or eyes with
water for at least 15 minutes. Get
medical attention for eyes.
11-977