TM 55-1520-240-23-9
11-214
INSTALL FORWARD LCT YOKE BEARINGS
(Continued)
11-214
8.
Turn yoke (2) over. Support other bearing
housing (7) on arbor press base (8). Position
yoke so that bearing housing bore is centered
over slot in arbor press base.
9.
Position spacer (9) in yoke (2) so that it is
centered on inner race of lower bearing (3).
10.
Install 12 inch bolt (10) through lower bearing (3),
spacer (9), and bearing housing (7).
NOTE
Work quickly with chilled bearing.
Bearing must be installed before it
warms.
11.
Remove bearing (4) from carbon dioxide (E92)
and wipe clean and dry. Use cloth (E120). Wear
goggles to protect eyes. Wear Kevlar gloves
(E187).
Press in bearing only until spacer is
lightly gripped between inner races
of bearings. Yoke will not operate
properly if bearing is incorrectly in
stalled.
12.
While epoxy primer (E292) is wet, press bearing
(4) into housing (7) (TM 55-1500-322-24).
13.
Remove bolt (10).
14.
Remove yoke assembly (2) from arbor press
base (8).
15.
Wipe off excess primer from yoke (2). Use cloth
(E120).
INSPECT
FOLLOW-ON MAINTENANCE:
None
END OF TASK
11-847