TM 55-1520-240-23-9
11-44
RIG PITCH OVERTRAVEL STOP
(Continued)
11-44
Acetone (E20) can form toxic
vapors if exposed to flame. Use in
well-ventilated area, away from open
flame. In case of contact, immediately
flush skin or eyes with water for
at least 15 minutes. Get medical
attention for eyes.
13.
Clean sealant from flange (24) and inside surface
(25) of access. Use acetone (E20) and cloths
(E120). Use goggles for eyes. Use gloves
(E186).
Wires must not support housing;
otherwise, damage to equipment
could occur.
14.
Support housing (16). Remove strap (20).
Sealant (E336) can irritate skin and
cause burns. Avoid contact with skin,
eyes, and clothing. In case of contact,
immediately flush skin or eyes with
water for at least 15 minutes. Get
medical attention for eyes.
15.
Apply sealant (E336) to both sides of new gasket
(19). Install gasket on flange (24). Use gloves
(E186).
16.
Remove excess sealant with acetone (E20) and
cloths (E120). Use goggles for eyes. Use gloves
(E186).
17.
Tilt housing assembly (16) and position up and
inside access (17), lamp (26) aft. Align housing
and access holes (27).
11-190