TM 55-1520-240-23-9
11-43
RIG PILOTS OR COPILOTS THRUST CONTROL
(Continued)
11-43
Acetone (E20) can form toxic
vapors if exposed to flame. Use in
well-ventilated area, away from open
flame. In case of contact, immediately
flush skin or eyes with water for
at least 15 minutes. Get medical
attention for eyes.
27.
Clean sealant from flange (35) and inside surface
(36) of access. Use goggles, acetone (E20), and
cloths (E120). Use gloves (E186).
28.
Support right housing assembly (5). Remove
strap (37).
Sealant (E336) can irritate skin and
cause burns. Avoid contact with skin,
eyes, and clothing. In case of contact,
immediately flush skin or eyes with
water for at least 15 minutes. Get
medical attention for eyes.
29.
Apply sealant (E336) to both sides of gasket
(38). Install gasket on flange (35).
30.
Remove excess sealant with acetone (E20) and
cloths (E120). Use goggles for eyes. Use gloves
(E186).
31.
Tilt housing assembly (5) and position up and
inside access (22), lamp (39) aft. Align housing
and access holes (40).
32.
Repeat steps 27 thru 31 for left housing, then
go to step 33.
11-182