TM 55-1520-240-23-9
11-277
BENCH TEST AFCS COMPUTER (AVIM)
(Continued)
11-277
243.
Set METER RANGE switch (7) to 2V. Read
AC/DC VOLTMETER (10). Reading shall be
-0.05 to +0.05.
244.
Set METER switch (6) to AC.
245.
Set CIRCUIT SELECT A UNITS switch (18) to 8.
Reading shall be +0.721 to +1.082.
246.
Set CIRCUIT SELECT A UNITS switch (18) to 9.
Read AC/DC VOLTMETER (10). Reading shall
be +0.361 to +0.541.
247.
Set CIRCUIT SELECT TENS switch (8) to 00.
Read AC/DC VOLTMETER (10). Reading shall
be +0.361 to +0.541.
248.
Set ANALOG SIGNALS ROLL RATE switch (30)
to 2.
249.
Set SERVO SIMULATION ILCA SIMULATION
ROLL switch (52) to RESET.
250.
Set METER RANGE switch (7) to 20V.
251.
Set METER switch (6) to DC.
252.
Set DISCRETE SIGNALS CYCLIC BRAKE
switch (27) to 1 momentarily and then to 0.
253.
Set ANALOG SIGNALS XFEED ROLL ATT
switch (53) to 3.
254.
Set CIRCUIT SELECT TENS switch (8) to 20.
255.
Set CIRCUIT SELECT A UNITS switch (18) to 6.