194.
Set RESPONSE TEST STIM switch (44) to
REMOVE.
195.
Set ANALOG SIGNALS ROLL RATE switch (30)
to 2.
196.
Set ANALOG SIGNALS LAT CPT switch (29)
to 2.
197.
Set RESPONSE TEST TIME DELAY-SEC
switches (40) to 1.5.
198.
Set RESPONSE TEST STIM switch (44) to
APPLY. When HOLD lamp (45) comes on, read
and record V4 AC/DC VOLTMETER (10) reading.
199.
Calculate V5. Subtract reading of step 187 from
reading of step 198 (V5 = V4 - V1). Result shall
be -5.76 to -8.29 volts.
200.
Set RESPONSE TEST STIM switch (44) to
REMOVE.
201.
Set RESPONSE TEST TIME DELAY-SEC
switches (40) to 4.0. Wait 60 seconds.
202.
Set RESPONSE TEST STIM switch (44) to
APPLY. When HOLD lamp (45) comes on, read
and record V6 AC/DC VOLTMETER (10) reading.
203.
Calculate V7. Subtract reading of step 187 from
reading of step 202 (V7 = V6 - V1). Result shall
be -3.52 to -5.06 volts.
204.
Set RESPONSE TEST STIM switch (44) to
REMOVE.
205.
Set ANALOG SIGNALS LAT CPT switch (29)
to 3.
206.
Set ANALOG SIGNALS ROLL ATT switch (50)
to 2.