TM 55-1520-240-23-9
11-276.1 ADJUST SIDESLIP AIRSPEED OR BAROMETRIC ALTITUDE PRESSURE TRANSDUCER,
AFCS COMPUTER (AVIM) (Continued)
11-276.1
3.
Set METER switch (5) to DC.
4.
Set NORM ACCEL J2-52 switch (6) to GND.
5.
Set METER RANGE switch (7) to 200 MV.
SIDESLIP TRANSDUCER
6.
Set CIRCUIT SELECT TENS switch (8) to 30.
7.
Set CIRCUIT SELECT A UNITS switch (9) to 7.
8.
Set CIRCUIT SELECT A/B switch (10) to A.
9.
Turn screw (11) of sideslip transducer
potentiometer (12) until VOLTMETER (13)
indicates -0.005 vdc. VOLTMETER must
indicate between -0.007 to -0.003.
AIRSPEED TRANSDUCER
10.
Set CIRCUIT SELECT TENS switch (8) to 40.
11.
Set CIRCUIT SELECT A UNITS switch (9) to 0.
12.
Turn screw (14) of airspeed transducer
potentiometer (15) until VOLTMETER (13)
indicates -0.005 vdc. VOLTMETER must
indicate between -0.010 to +0.000.
Change 1
11-1067