TM 55-1520-240-23-9
11-271
ASSEMBLE AFCS CONTROL PANEL (AVIM)
(Continued)
11-271
25.
Position connector bracket (4) on four support
rods (34) and install four screws (48). Use
sealant (E345).
26.
Install braided nomex tape (E403) as necessary
to wire harness (49). After tying nomex tape,
apply adhesive (E62) to knots.
27.
Position rear cover (50) over connector bracket
(4).
28.
Engage and lock two fasteners (51). Fasteners
require 1/4 turn clockwise to lock.
FOLLOW-ON MAINTENANCE:
Bench test AFCS control panel (Task 11-272).
END OF TASK
11-1032