TM 55-1520-240-23-9
11-270.1
REPLACE AFCS CONTROL PANEL NON-NVG (RED) LENSES WITH NVG (BLUE/GREEN)
LENSES
(Continued)
11-270.1
11.
Position front illumination panel (42) on front
mount panel (15). Make sure lamp receptacle
connector (14) and illumination panel plug (43)
snap together.
Sealant can irritate and cause
burns. Avoid contact with skin, eyes,
or clothing. In case of contact,
immediately flush skin or eyes with
water for at least 15 minutes. Get
medical attention for eyes.
12.
Install three screws (44). Use sealant (E345)
on screws.
13.
Position knob (45) on switch shaft (46) and
tighten two setscrews (47).
14.
Position rear cover (50) over assembly (4).
15.
Engage lock and two fasteners (51). Fasteners
require 1/4 turn clockwise to lock.
FOLLOW-ON MAINTENANCE:
Bench test AFCS control panel (Task 11-272).
END OF TASK
11-1026