TM 55-1520-240-23-8
10-5
INSPECT FUEL TANKS HARD LANDING
(Continued)
10-5
f.
Check two lanyard-release electrical
connectors (14). Connectors shall be secure.
INSPECT FORWARD FUEL TANK
NOTE
Procedure is same to inspect either
forward fuel tank after suspected hard
landing. Left side is shown here.
2.
Check forward fuel tank (15) as follows:
a.
Check access door (16) on aft end of tank
(15). Door shall be secure and there shall be
no missing bolts (17).
b.
Check fittings (18, 19, and 20) on aft end of
tank (15). Fittings shall be secure.
c.
Check access door (21) on forward end of
tank. Door shall be secure and there shall be
no missing bolts (22).
d.
Check areas around tank unit (23) and tank
filler adapter (24). There shall be no missing
rivets.
e.
Check lanyard-release electrical connector
(25). Connector shall be secure.
10-36